Numerical investigation on the low NOx emission of W-shaped radiant tubes
-
-
Abstract
To cope with the high NOxemission problem of W-shaped radiant tubes,the influence of diluents in two-stage air combustion on the NOxemission of W-shaped radiant tubes was investigated numerically. Calculation results coincide well with data obtained from experiments. The analysis was carried out for 3 cases:different diluents,stepwise dilution,and diluents together with high temperature air. Compared to diluting with N2,diluting with CO2 produces less NOx. It can reduce the NOxemission blow 4 ×10-5 by increasing the diluted volume fraction under the condition of ensuring flame stabilization. By stepwise dilution,the secondary air contributes more to NOxreduction than the primary air. The NOxemission can be controlled under 1 × 10-4 by increasing the diluted volume fraction,even if the temperature of preheated air reaches above 1000℃.
-
-