光导纤维多色辐射测温原理探讨

Temperature Measurement with Optical Fiber and Multi-Wavelengthes by Radiation

  • 摘要: 多色测温仪是近年来国内外进行了较多研究的课题之一,它对于削弱表面辐射系数对测温精度的影响有较好的效果。
    本文设计了一种多色辐射测温仪。运用经典的普朗克公式,由表面黑度系数的幂级数形式,从理论上推导了多色辐射测温公式。并讨论了这个公式对于克服黑度系数影响的作用以及它的测温误差。
    多色测温仪设计中采用光导纤维光学系统,实现了被测辐射信号的传输及对四个光电元件的分叉耦合。利用单板计算机进行回色信号处理。仪表经黑体炉标定,并针对不同金属耙面,研究了四色温度与比色温度的误差。
    仪表经计量部门标定及实验室试验,认为多色测温技术是消弱表面黑度系数对测温精度影响的有效方法之一。

     

    Abstract: The paper describes a multi-wavelengthes pyrometer. The pyrometer is based on the planck's law. And it is assumed that the logarithm of emissivity is approximated by its polynomial in terms of wavelength. A representation of four-colour pyrometer is designed. The representing temperature of four-colour wavelength pyrometer come from that of ratiocolour wavelength pyrometers.TF-1, reciprocal of four-colour temperature is the linear combination of the TR1-1 and TR2-1 reciprocal of two ratio temperature. The coefficients of the linear combination are decided by the respective wavelengthes. If one of wavelengthes chosed by a ratio is equal to another one of wavelengthes chosed by the other, the four-colour pyrometer is going to become three-colour one. The four-colour(or threecolour) temperature cuts off the error caused by the influence of the emissivity, with 1n ε assumed as being linear in wavelength.
    A optical fiber is used to transmit the radiation emitted by the measured target. It is the use of technique of optical fiber branch that incoming radiation is distributed to the surface of each dectector. A microprocessor is used to calculated the four-colour signal of radiation. The result of the calibration was gived out by the blackbody furnace. The error of four-colour temperature is compared with that of ratio temperature by the experiment on some metal target.
    It is said that the technique of multi-wavelength temperature measurement is one. of effective method to decrease the error caused by the emissivity of the measured surface.

     

/