殷明志, 邵光玓, 陈华序. 增敏剂对多元惰性铬(Ⅲ)显色配合物的影响 Ⅱ、《铬(Ⅲ)-铬菁R-增敏剂》体系[J]. 工程科学学报, 1989, 11(3): 270-275. DOI: 10.13374/j.issn1001-053x.1989.03.028
引用本文: 殷明志, 邵光玓, 陈华序. 增敏剂对多元惰性铬(Ⅲ)显色配合物的影响 Ⅱ、《铬(Ⅲ)-铬菁R-增敏剂》体系[J]. 工程科学学报, 1989, 11(3): 270-275. DOI: 10.13374/j.issn1001-053x.1989.03.028
Yin Mingzhi, Shao Guangdi, Chen Huaxu. The influence of Sensitizer to the Colored Inert Chromium(Ⅲ) Multicomponent Complex(Ⅱ). The System of “Chromiun(Ⅲ)——Eriochrome Cyanine R——Sensitizer”[J]. Chinese Journal of Engineering, 1989, 11(3): 270-275. DOI: 10.13374/j.issn1001-053x.1989.03.028
Citation: Yin Mingzhi, Shao Guangdi, Chen Huaxu. The influence of Sensitizer to the Colored Inert Chromium(Ⅲ) Multicomponent Complex(Ⅱ). The System of “Chromiun(Ⅲ)——Eriochrome Cyanine R——Sensitizer”[J]. Chinese Journal of Engineering, 1989, 11(3): 270-275. DOI: 10.13374/j.issn1001-053x.1989.03.028

增敏剂对多元惰性铬(Ⅲ)显色配合物的影响 Ⅱ、《铬(Ⅲ)-铬菁R-增敏剂》体系

The influence of Sensitizer to the Colored Inert Chromium(Ⅲ) Multicomponent Complex(Ⅱ). The System of “Chromiun(Ⅲ)——Eriochrome Cyanine R——Sensitizer”

  • 摘要: 本文报导了另一个新的增敏型多元惰性铬(Ⅲ)显色配合物体系。当两性增敏剂烷基二甲氨基乙酸作为<铬(Ⅲ)-铬菁R-增敏剂>体系中的增敏剂时,此显色体系的灵敏性虽比前文所报导的显色体系稍低一点,但对某些外来离子的选择性来说,自有其优点;况且当烷基为十四烷基及十六烷基时,摩尔吸光系数分别为1.22×105及1.14×105,灵敏性仍比其它已报导的体系为佳。探索了形成此多元惰性显色配合物的形成条件、组成及其在测定微量铬时的应用。

     

    Abstract: In this paper, another new sensitized colored multicomponent coordination compound in the system of "Chromium(Ⅲ)——Eriochrome cyanineR——Alkyl dimethy laminoacelic acid" has been developed. The optimum conditions for the formation of the coordination compound in this system have been studied. It will not be decomposed by various masking agents such as EDTA, CyDTA, citric acid, tartaric acid etc; while in that case, almost all the colored coordination compounds formed by other ions will be decomposecompletely. This inert character of this multicomponent coordination compound and its utilization in improving the analytical selectivity have been discussed. In the coexistence of various foreign ions, the direct determination of chromium has shown a satisfactory reproducibility. It was also proved as our former report that the sensitizer cetyl dimethylaminoacetic acid(CDMAA) or tetradecyl dimethylaminoacetic acid(TDMAA) is more suitable to be used in the spectro-photometric determination of microamount of chromium with high sensitivity. When CDMAA and TDMAA are used as sensitizer in this system, the molar absorptivity are 1.14×105 and 1.22×105 respectively. From the results of determination in some synthetic and actual samples, it showed feasible to use this system in the determination of low chromium in steels and microamount of chromium in the waste water from elctroplating or other industries.

     

/

返回文章
返回