Han Haiou. An Investigation on the Sulfur Determination by Using MgS-Based Solid Electrolyte[J]. Chinese Journal of Engineering, 1987, 9(S2): 75-81. DOI: 10.13374/j.issn1001-053x.1987.s2.022
Citation: Han Haiou. An Investigation on the Sulfur Determination by Using MgS-Based Solid Electrolyte[J]. Chinese Journal of Engineering, 1987, 9(S2): 75-81. DOI: 10.13374/j.issn1001-053x.1987.s2.022

An Investigation on the Sulfur Determination by Using MgS-Based Solid Electrolyte

  • MgS and TiS2 were made at lab and the MgS-TiS2(2%) disks were sintered at high temperature. A sulfur sensor using the MgS-based solid electrolyte was prepared and the galvanic cell can be expressed by Mo |SFe| MgS-TiS2(2%) |Mo, MoS2| Mo. The sulfur determination in liquid iron was carried out at 1375℃ without any protective atmosphere. The relation between the measured E and the chemical analysis %S can be shown as los%S=-0.3694-0.0077E(mV)(%S, 0.003-0.134). Also,the determination of the sulfur potential of the (u-Cu2S system shows that the partial electronic conduction parameter Pe’ is 6×10-4 Pa for the MgS-TiS2(2%) solid electrolyte at 1375℃.Pe’and fs were introduced for the correction of the E-%S relation.