Investigation of Hot Corrosion of Great Wall No.1 Coating
-
-
Abstract
High temperture corrosion tests in 75%Na2SO4-25%NaCl molten salt have been conducted on GH864 superalloy specimens plasma sprayed with great wall No.1 and X-40 coatings. After the corrosion tests,each sample was examined by OM, SEMand EMPA.It was found that X-40 coating was severely corroded by the molten salt due to cracking and spalling, whereas the Great Wall No.1 exhibited superior corrosion resistance.
-
-