Pu Xiaoping, Ma Xianghua, Chen Kexing, Shao Yimin. Real Running Condition Experiment and Diagnostic Method for Cone Bearing Failure and Cylinder Bearing Failure[J]. Chinese Journal of Engineering, 1993, 15(5): 517-520. DOI: 10.13374/j.issn1001-053x.1993.05.034
Citation: Pu Xiaoping, Ma Xianghua, Chen Kexing, Shao Yimin. Real Running Condition Experiment and Diagnostic Method for Cone Bearing Failure and Cylinder Bearing Failure[J]. Chinese Journal of Engineering, 1993, 15(5): 517-520. DOI: 10.13374/j.issn1001-053x.1993.05.034

Real Running Condition Experiment and Diagnostic Method for Cone Bearing Failure and Cylinder Bearing Failure

  • The experiments for cone bearing and cylinder bearing failures base on real running condition test (not analogue) in a bearing test machine. The vibration and temperature signals are monitored. The signal analysis method, diagnostic parameters choise method,time waveform and spectrum are studied deeply. Many valuable conclusions are obtained and a aood diagnostic is found.