ZHANG Junyan, SONG Cunyi, WANG Liying, JIN Yanhui. Minimum ignition temperature of meager-lean coal for BF injection[J]. Chinese Journal of Engineering, 2006, 28(8): 785-789. DOI: 10.13374/j.issn1001-053x.2006.08.018
Citation: ZHANG Junyan, SONG Cunyi, WANG Liying, JIN Yanhui. Minimum ignition temperature of meager-lean coal for BF injection[J]. Chinese Journal of Engineering, 2006, 28(8): 785-789. DOI: 10.13374/j.issn1001-053x.2006.08.018

Minimum ignition temperature of meager-lean coal for BF injection

  • In view of safety the elementary and industrial analyses of coal samples were conducted, a systematic experiment was performed to investigate the minimum ignition temperature (MIT) of Zhangcun and Changcun meager-lean coal in a G-G furnace, and the effect of dust concentration, spray-air pressure and dust particle size on the MIT was analyzed. The results show that the TIM increases with the decrease of dust concentration and the increase of spray-air pressure and dust particle size. A linear regression was conducted and the functional relationship was found, which can afford reference for the security of meagerlean coal's industry application.
  • loading

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return