ZHANG Shaojun, XU Xiaohua, YANG Chunyan, LI Zhongfu, ZHAO Ying. Flux uniformity at the nozzle pipe outlet of a four-branch pipe controlled cooling apparatus for steel plates[J]. Chinese Journal of Engineering, 2008, 30(10): 1154-1157. DOI: 10.13374/j.issn1001-053x.2008.10.001
Citation: ZHANG Shaojun, XU Xiaohua, YANG Chunyan, LI Zhongfu, ZHAO Ying. Flux uniformity at the nozzle pipe outlet of a four-branch pipe controlled cooling apparatus for steel plates[J]. Chinese Journal of Engineering, 2008, 30(10): 1154-1157. DOI: 10.13374/j.issn1001-053x.2008.10.001

Flux uniformity at the nozzle pipe outlet of a four-branch pipe controlled cooling apparatus for steel plates

  • A three-dimensional steady simulation of the flow in the four-branch pipe of a controlled cooling device was carried out by the numerical simulation calculation method of finite element coupling field. The effect of nozzle pipe diameter, nozzle pipe height, branch pipe diameter, and inlet velocity on the flux uniformity at the nozzle pipe outlet was analyzed. The result of simulation show that nozzle pipe diameter, branch pipe diameter and inlet velocity have a great influence on the flux uniformity at the nozzle pipe outlet, but nozzle pipe height has a little influence on it.
  • loading

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return