Interactive influence of environmental factors on the pitting susceptibility of X120 pipeline steel studied by a uniform design method
-
-
Abstract
A uniform design experimental method was employed to discuss the interactive influence of Cl- concentration, pH values and temperature on the pitting susceptibility of X120 pipeline steel in HCO3- + Cl- solutions by a potentiodynamic scan technique. The experimental results indicate that Cl-- concentration, pH values and temperature have great effect on the corrosion and passive behavior of X120 pipeline steel in HCO3- + Cl- solutions, and the influence order is as follows:Cl- concentration has the greatest impact, then the combined action of Cl- concentration and temperature, the third one is pH values, and temperature has the smallest impact. X120 pipeline steel has the least pitting susceptibility in the HCO3- + Cl- solution whose C1 concentration is 0 mol·L-1, pH value is 8.5 and temperature is 0℃.
-
-